{"id":635,"date":"2015-03-18T07:52:14","date_gmt":"2015-03-18T07:52:14","guid":{"rendered":"http:\/\/www.etfos.unios.hr\/ijeces\/?p=635"},"modified":"2017-03-23T08:04:47","modified_gmt":"2017-03-23T08:04:47","slug":"using-an-evolutionary-algorithm-for-harmonic-load-modeling-by-norton-and-thevenin-equivalents","status":"publish","type":"post","link":"http:\/\/www.etfos.unios.hr\/ijeces\/vol-5-no-2-2014\/using-an-evolutionary-algorithm-for-harmonic-load-modeling-by-norton-and-thevenin-equivalents\/","title":{"rendered":"Using an Evolutionary Algorithm for Harmonic Load Modeling by Norton and Thevenin Equivalents"},"content":{"rendered":"<div  class=\"fusion-fullwidth fullwidth-box hundred-percent-fullwidth\"  style='background-color: rgba(255,255,255,0);background-position: center center;background-repeat: no-repeat;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;'><div class=\"fusion-builder-row fusion-row \"><div  class=\"fusion-layout-column fusion_builder_column fusion_builder_column_1_1  fusion-one-full fusion-column-first fusion-column-last fusion-column-no-min-height 1_1\"  style='margin-top:0px;margin-bottom:0px;'>\n\t\t\t<div class=\"fusion-column-wrapper\" style=\"background-position:left top;background-repeat:no-repeat;-webkit-background-size:cover;-moz-background-size:cover;-o-background-size:cover;background-size:cover;\"  data-bg-url=\"\">\n\t\t\t\t<div class=\"fusion-title title fusion-title-size-three\" style=\"margin-top:0px;margin-bottom:31px;\"><h3 class=\"title-heading-left\">Domagoj Biland\u017eija, Marinko Baruk\u010di\u0107, Venco \u0106orluka<\/h3><div class=\"title-sep-container\"><div class=\"title-sep sep-single sep-solid\" style=\"border-color:#1e73be;\"><\/div><\/div><\/div><div class=\"fusion-sep-clear\"><\/div><div class=\"fusion-separator fusion-full-width-sep sep-single sep-dashed\" style=\"border-color:#1e73be;border-top-width:1px;margin-left: auto;margin-right: auto;margin-top:;margin-bottom:10px;\"><\/div><div data-canvas-width=\"600.915\"><strong>Abstract<\/strong><\/div>\n<div data-canvas-width=\"600.915\">The Norton equivalent model for harmonic load modeling is used widely. The parameters of the model are usually calculated analytically. These calculations are based on measured or simulated voltage\/current waveforms. In this case, harmonic analysis is needed to obtain the harmonic spectra. After this step, model parameter values are calculated for each harmonic separately. Relative phase shifts of all measured harmonic voltages and currents are most important for correct calculation of Norton model parameters. Different estimations in the power network are used to determine the phase shifts. The use of an evolutionary algorithm to determine the voltage and current harmonic phase shifts is researched in the paper. The proper optimization problem is defined and an evolutionary algorithm is used to solve the problem. The verification of the method will be done by comparing simulated waveforms obtained by a computer program.<\/div>\n<div class=\"fusion-sep-clear\"><\/div><div class=\"fusion-separator fusion-full-width-sep sep-single sep-dashed\" style=\"border-color:#1e73be;border-top-width:1px;margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;\"><\/div><div data-canvas-width=\"70\"><strong>Keywords<\/strong><\/div>\n<div data-canvas-width=\"403.605\">heuristic optimization, highdimensional optimization, nature-inspired algorithms, optimization techniques.<\/div>\n<div class=\"fusion-sep-clear\"><\/div><div class=\"fusion-separator fusion-full-width-sep sep-single sep-dashed\" style=\"border-color:#1e73be;border-top-width:1px;margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;\"><\/div><p><a href=\"http:\/\/www.etfos.unios.hr\/ijeces\/wp-content\/uploads\/2015\/03\/05-02-14-02.pdf\" target=\"_blank\"><\/p>\n<div class=\"alignleft\"><i class=\"fa fontawesome-icon fa-file-text-o circle-yes\" style=\"border-color:#ffffff;background-color:#1e73be;font-size:15.84px;line-height:31.68px;height:31.68px;width:31.68px;margin-right:9px;color:#ffffff;\"><\/i><\/div><p><\/a><\/p>\n<div class=\"fusion-clearfix\"><\/div>\n\n\t\t\t<\/div>\n\t\t<\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[47],"tags":[],"_links":{"self":[{"href":"http:\/\/www.etfos.unios.hr\/ijeces\/wp-json\/wp\/v2\/posts\/635"}],"collection":[{"href":"http:\/\/www.etfos.unios.hr\/ijeces\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.etfos.unios.hr\/ijeces\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.etfos.unios.hr\/ijeces\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"http:\/\/www.etfos.unios.hr\/ijeces\/wp-json\/wp\/v2\/comments?post=635"}],"version-history":[{"count":2,"href":"http:\/\/www.etfos.unios.hr\/ijeces\/wp-json\/wp\/v2\/posts\/635\/revisions"}],"predecessor-version":[{"id":1125,"href":"http:\/\/www.etfos.unios.hr\/ijeces\/wp-json\/wp\/v2\/posts\/635\/revisions\/1125"}],"wp:attachment":[{"href":"http:\/\/www.etfos.unios.hr\/ijeces\/wp-json\/wp\/v2\/media?parent=635"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.etfos.unios.hr\/ijeces\/wp-json\/wp\/v2\/categories?post=635"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.etfos.unios.hr\/ijeces\/wp-json\/wp\/v2\/tags?post=635"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}